Automatic Coagulation Analyzer Ci-300

Ci-300 is a fully automatic bench top analyzer consisting of an analytical module and a control module.
 Operates on whole blood or  platelet-poor plasma  platelet-poor plasma
 platelet-poor plasma  racks, primary tubes
 Model type  benchtop
 Dimensions (H × W × D)
 Dimensions (H × W × D)- Outer packing
 650mm×1030mm ×720mm
 890mm×1200mm ×850mm
 Weight- analyzer
 Weight- Outer packing
 140kg
 180kg
 Electric Ratings:  ac. 110-240V, 50/60Hz, <1200VA
 Ambient Temperature:   Between 15℃ and 30℃
 Relative Humidity:  Between 30% and 85 %
 Methodologies supported  clot detection (LED optical  transmission method); chromogenic;   immunologic;
 Wavelength  405nm;545nm;670nm;800nm
 Number of different measured assays onboard   simultaneously  30
 Number of different assays programmed and calib.   at   one time  unlimited
 Factor assays require manual manipulation or   dilutions  No
 Number of reagent containers onboard at once  36 (reagent area,8℃)+10(dilution area,12℃)=46
 Multiple reagent configurations supported  Yes
 Walkaway capacity: Number of specimens/Number of   tests  50/up to 1000
 Minimum sample volume aspirated precisely at one   time  3ul
 Standard specimen volume required to run PT or   PTT/Factor VIII activity  50ul/25ul
 Primary tube sampling supported/Pierces caps on   primary  tubes  Yes/No
 Sample bar-code reading capability  Yes
 Reagent bar-code reading capability  Yes
 Onboard test automatic inventory  Yes
 Measures No. of tests remaining/Short sample detection  Yes/Yes
 Auto. detects adequate reagents for aspiration and   analysis  Yes
 Dilution of patient samples onboard  Yes
 Automatic rerun capability/Auto reflex testing capability  Yes
 Read time extended for prolonged clotting times  Yes
 User can set different-than-standard  1) Reagent volumes/Sample volumes;
 2) No. and sources of reagent;
 3) Incub. times/Reading times;
 Autocalib. or autocalib. alert/Multipoint calib. supported  Yes
 Stat time to complete all analyses/Throughput per hour   for:  PT Alone:≦6 minutes/300 specimens
 PT, PTT(MIX):≦6 minutes/300 specimens
 D-Dimer:≦6 minutes/300 specimens
 Factor VIII activity assay:≦11 minutes/150 specimens
 Time delay from ordering STAT to aspiration of sample  minimal
 Number of Measurements  At each standard point, up to 5 simultaneous multi-parameter   analysis is available.
 Automatic transfer of QC results to LIS  Yes
 Protection Function  Over-heat Protection Fuse
 Mechanical stop switch
 Cover open/close sensor
 Probe protection sensor
 Over-current Protection Fuse
 Unit Error Alert Function  Instrument Abnormality-Monitoring Function
 1) Temperature at heating/cooling section
 2) Presence or absence of reagent racks
 3) Shortage of reagent
 4) Presence or absence of cuvette
 5) Shortage of buffer or rinse solution
 6) Operation of mechanical parts
 7) Other self-diagnosis by service mode

 Sample Abnormality-Monitoring Function
 1) Upper and Lower Limit Judgement
 2) Automatic Re-dilution Analysis (for the dilution analysis   parameter only)
 3) Reflex Testing
 automatic supply reaction cuvettes  Yes

 

 

;